startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|T2Set.y|con.T2Sup.T|con.T2Ret.T|T1Sup.T|T1Ret.T|con.val.y_actual|pum.m_flow|con.pum.m_flow|con.res3.m_flow|mPum_flow_nominal|con.mPum_flow_nominal|fraLoa.y.1.|fraLoa.y.2.|loa.yLoa_actual|loa1.yLoa_actual|loa.con.val.y_actual|loa1.con.val.y_actual|dp1SetVal.y|dp1.p_rel|dp2SetVal.y|dp2.p_rel|pum.y_actual|con.pum.y_actual|TSupOpe.T|TRetOpe.T|loaOpe.yLoa_actual",fileNamePrefix="Buildings_latest_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn",simflags="-alarm=800 -emit_protected -lv LOG_STATS") LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:78:3-83:35:writable] | | | | The following assertion has been violated at time 36391.680000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:78:3-83:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.31009e-44" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -5.86337e-41" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.eff.yMot, has value: -5.67195e-73" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.etaHyd, has value: -1.3834e-60" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79280.640000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -3.62457e-47" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 8 state events LOG_STATS | info | | 4 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 2848 steps taken LOG_STATS | info | | 4364 calls of functionODE LOG_STATS | info | | 555 evaluations of jacobian LOG_STATS | info | | 220 error test failures LOG_STATS | info | | 27 convergence test failures LOG_STATS | info | | 1 linear system solves LOG_SUCCESS | info | The simulation finished successfully.