startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 wasm-jit simulation: simulate(Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_OnDemandResistiveDefrost,startTime=0,stopTime=172800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|TOutDegC.Celsius|TOutEPlu.y|XConOut.y|XConOutEPlu.y|Q_flowMea.y|Q_flowEPlu.y|PMea.y|PEPlu.y",fileNamePrefix="Buildings_latest_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_OnDemandResistiveDefrost",simflags="-alarm=800 -emit_protected -lv LOG_STATS") LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Fluid/DXSystems/Heating/AirSource/Validation/SingleSpeedHeating_OnDemandResistiveDefrost/DXCoilSystemAuto.dat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:138:7-151:38:writable] | | | | The following assertion has been violated at time 36000.000000 | | | | ((not (sinSpeDX.dxCoi.TConIn > 296.47999999999996 or sinSpeDX.dxCoi.TConIn < 290.92999999999995))) --> "*** Warning: Condenser temperature TConIn is out of bounds in DX coil model at time = 36000. | | | | stage = 1 | | | | TConInMin = 290.93 Kelvin (17.78 degC) | | | | TConIn = 284.92 Kelvin (11.77 degC) | | | | TConInMax = 296.48 Kelvin (23.33 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/BaseClasses/PartialCoilInterface.mo:26:3-29:72:writable] | | | | The following assertion has been violated at time 36000.000000 | | | | ((sinSpeDX.dxCoi.Q_flow <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.Q_flow <= 0.0, has value: 12587.4" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/DXSystems/Cooling/BaseClasses/SpeedShift.mo:10:3-11:76:writable] | | | | The following assertion has been violated at time 36000.000000 | | | | ((sinSpeDX.dxCoi.speShiQ_flow.u[1] <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.speShiQ_flow.u[1] <= 0.0, has value: 12587.4" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 60 state events LOG_STATS | info | | 49 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 5945 steps taken LOG_STATS | info | | 3837 calls of functionODE LOG_STATS | info | | 2170 evaluations of jacobian LOG_STATS | info | | 76 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.