startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Applications.DataCenters.ChillerCooled.Examples.NonIntegratedPrimarySecondaryEconomizer,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|TAirSup.T|TAirSupSet.y|ahuValSig.y|TCHWSup.T|TCHWRet.T|TCHWSupSet.y|TCWSup.T|TCWRet.T|TCWSupSet.y|cooModCon.y|chiNumOn.y|cooTow.1..Q_flow|chiWSE.chiPar.chi.1..QEva_flow|chiWSE.wse.heaExc.hex.Q2_flow|ahu.cooCoi.Q2_flow",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Examples.NonIntegratedPrimarySecondaryEconomizer",simflags="-alarm=800 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ahu.fan.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= ahu.fan.etaHyd, has value: -4.59545e-21" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:55:3-65:65:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((cooTow[2].TAppCor >= 0.0)) --> "Variable violating min constraint: 0.0 <= cooTow[2].TAppCor, has value: -5.98901" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:47:3-48:28:writable] | | | | The following assertion has been violated at time 1200.000000 | | | | ((chiWSE.chiPar.chi[2].vol2.p >= 0.0 and chiWSE.chiPar.chi[2].vol2.p <= 1e8)) --> "Variable violating min/max constraint: 0.0 <= chiWSE.chiPar.chi[2].vol2.p <= 1e8, has value: 1.55474e+11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:39:3-40:53:writable] | | | | The following assertion has been violated at time 1200.000000 | | | | ((cooTow[2].FRWat >= 0.0 and cooTow[2].FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= cooTow[2].FRWat <= 1.0, has value: -4.58964e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:15:5-15:79:writable] | | | | The following assertion has been violated at time 1200.000000 | | | | ((priPum.pum[1].port_b.p >= 0.0 and priPum.pum[1].port_b.p <= 1e8)) --> "Variable violating min/max constraint: 0.0 <= priPum.pum[1].port_b.p <= 1e8, has value: 1.55474e+11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:15:5-15:79:writable] | | | | The following assertion has been violated at time 1200.000000 | | | | ((priPum.pum[2].port_b.p >= 0.0 and priPum.pum[2].port_b.p <= 1e8)) --> "Variable violating min/max constraint: 0.0 <= priPum.pum[2].port_b.p <= 1e8, has value: 1.55474e+11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 1208.039489 | | | | ((secPum.pum[2].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= secPum.pum[2].etaHyd, has value: -6.87373e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 1230.219826 | | | | ((priPum.pum[1].eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= priPum.pum[1].eff.yMot, has value: -7.11579e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 1230.219826 | | | | ((priPum.pum[2].eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= priPum.pum[2].eff.yMot, has value: -7.11579e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 1260.001004 | | | | ((priPum.pum[2].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= priPum.pum[2].etaHyd, has value: -4.19605e-23" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 32 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 3556 steps taken LOG_STATS | info | | 5267 calls of functionODE LOG_STATS | info | | 982 evaluations of jacobian LOG_STATS | info | | 267 error test failures LOG_STATS | info | | 28 convergence test failures LOG_STATS | info | | 100526 linear system solves LOG_SUCCESS | info | The simulation finished successfully.