startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=120 stepSize=3600 wasm-jit simulation: simulate(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,startTime=1.5552e+07,stopTime=1.5984e+07,tolerance=1e-06,numberOfIntervals=120,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Utilities.Plotters.Examples.SingleZoneVAV",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 15552000.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 15703200.000000 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -1.00974e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 15705778.306725 | | | | ((hvac.ideVal.preMasFlo.m_flow >= 0.0 and hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -1.00974e-28" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.0478e-05s [ 0.0%] pre-initialization | | | | | | 0.0281709s [ 2.8%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.144168s [ 14.4%] solver (excl. callbacks) | | | | | | 4.068e-06s [ 0.0%] creating output-file | | | | | | 0.123075s [ 12.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.704614s [ 70.5%] simulation | | | | | | 1.00006s [100.0%] total | | | | | events | | | | | | 41 state events | | | | | | 514 time events | | | | | solver: dassl | | | | | | 12856 steps taken | | | | | | 18008 calls of functionODE | | | | | | 6201 evaluations of jacobian | | | | | | 530 error test failures | | | | | | 1 convergence test failures | | | | | | 0.550724s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. LOG_STDOUT | info | Wrote plot file "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html".