startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|hex.Q2_flow|hex.QLat2_flow|hex.port_a1.m_flow|hex.port_a2.m_flow",fileNamePrefix="Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow",simflags="-alarm=400 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 1980.000000 | | | | ((hex.SHR >= 0.0 and hex.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hex.SHR <= 1.0, has value: -4.23764e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:364:5-373:38:writable] | | | | The following assertion has been violated at time 1998.720000 | | | | ((noEvent(hex.m1_flow > (-0.1) * hex.m1_flow_nominal) and noEvent(hex.m2_flow > (-0.1) * hex.m2_flow_nominal))) --> "*** Warning in WetCoilEffectivenessNTUMassFlow.hex: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 5 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 620 steps taken LOG_STATS | info | | 964 calls of functionODE LOG_STATS | info | | 171 evaluations of jacobian LOG_STATS | info | | 57 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.