startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|hex.m1_flow|hex.m2_flow|con.u_s|con.u_m|hex.Q1_flow|hex.Q2_flow|hex.QLat2_flow|hex.QSen2_flow",fileNamePrefix="Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning",simflags="-alarm=400 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOnRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOnRec.yRec.y, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOffRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOffRec.yRec.y, has value: 0" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 2400.000000 | | | | ((not con.falEdg.not_u)) --> "The set point must not change when an autotuning tuning is ongoing. | | | | This ongoing autotuning will be aborted and the control gains will not be changed." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/Utilities/PIDWithAutotuning/AutoTuner/AMIGO/PID.mo:26:3-31:72:writable] | | | | The following assertion has been violated at time 2487.823944 | | | | ((con.PIDPar.Ti >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.PIDPar.Ti, has value: -1.4424" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/Utilities/PIDWithAutotuning/Relay/ResponseProcess.mo:44:3-47:58:writable] | | | | The following assertion has been violated at time 2487.823944 | | | | ((con.resPro.tau >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.tau, has value: -7.41298" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/Utilities/PIDWithAutotuning/SystemIdentification/FirstOrderTimeDelay/BaseClasses/TimeConstantDelay.mo:25:3-31:58:writable] | | | | The following assertion has been violated at time 2487.823944 | | | | ((con.conProMod.timConDel.T >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.conProMod.timConDel.T, has value: -2.85715" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 2487.823944 | | | | ((con.conProMod.samT.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.conProMod.samT.y, has value: -2.85715" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 15 state events LOG_STATS | info | | 4 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 2522 steps taken LOG_STATS | info | | 3859 calls of functionODE LOG_STATS | info | | 708 evaluations of jacobian LOG_STATS | info | | 214 error test failures LOG_STATS | info | | 11 convergence test failures LOG_STATS | info | | 20979 linear system solves LOG_SUCCESS | info | The simulation finished successfully.