startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctSnapActing.Validation.Controller,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|duaDucCon.TZon|duaDucCon.TCooSet|duaDucCon.THeaSet|duaDucCon.TDis|duaDucCon.TColSup|duaDucCon.THotSup|duaDucCon.u1Win|duaDucCon.u1Occ|duaDucCon.uOpeMod|duaDucCon.ppmCO2|duaDucCon.VColDucDis_flow|duaDucCon.VHotDucDis_flow|duaDucCon.oveFloSet|duaDucCon.oveCooDamPos|duaDucCon.oveHeaDamPos|duaDucCon.u1CooAHU|duaDucCon.u1HeaAHU|duaDucCon.VSet_flow|duaDucCon.yCooDam|duaDucCon.yHeaDam|duaDucCon.yZonCooTemResReq|duaDucCon.yColDucPreResReq|duaDucCon.yLowFloAla|duaDucCon.yColFloSenAla|duaDucCon.yColLeaDamAla",fileNamePrefix="Buildings_12_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctSnapActing.Validation.Controller",simflags="-alarm=400 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated." LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 53 state events LOG_STATS | info | | 724 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 11151 steps taken LOG_STATS | info | | 12895 calls of functionODE LOG_STATS | info | | 9570 evaluations of jacobian LOG_STATS | info | | 47 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.