startTime=1.87488e+07 stopTime=1.93536e+07 tolerance=1e-06 numberOfIntervals=2513 stepSize=240.669 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer,startTime=1.87488e+07,stopTime=1.93536e+07,tolerance=1e-06,numberOfIntervals=2513,outputFormat="mat",variableFilter="time|zon.TAir|equEle.y",fileNamePrefix="Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer",simflags="-alarm=400 -emit_protected -lv LOG_STATS") LOG_STDOUT | info | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 18748800.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.08.21 19:29 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/10/2017 Continuing Simulation at 02/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/02/2017 Continuing Simulation at 03/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/22/2017 Continuing Simulation at 03/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/11/2017 Continuing Simulation at 04/11/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/01/2017 Continuing Simulation at 05/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/21/2017 Continuing Simulation at 05/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/10/2017 Continuing Simulation at 06/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/30/2017 Continuing Simulation at 06/30/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/20/2017 Continuing Simulation at 07/20/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. Updating Shadowing Calculations, Start Date=08/09/2017 Continuing Simulation at 08/09/2017 for SPAWN-RUNPERIOD LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 504 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 10004 steps taken LOG_STATS | info | | 13144 calls of functionODE LOG_STATS | info | | 6048 evaluations of jacobian LOG_STATS | info | | 263 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 47912 linear system solves LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 2.58sec EnergyPlus Completed Successfully.