startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=10159 stepSize=42.5239 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Summer,startTime=1.6848e+07,stopTime=1.728e+07,tolerance=1e-07,numberOfIntervals=10159,outputFormat="mat",variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TZonSet.1..TCooSet|hvac.TZonSet.1..THeaSet|hvac.fanSup.y|hvac.VAVBox.5..vav.y_actual|hvac.VAVBox.1..vav.y_actual|hvac.VAVBox.2..vav.y_actual|hvac.VAVBox.3..vav.y_actual|hvac.VAVBox.4..vav.y_actual|hvac.damOut.y|hvac.VAVBox.1..TSup|hvac.VAVBox.2..TSup|hvac.VAVBox.3..TSup|hvac.VAVBox.4..TSup|hvac.VAVBox.5..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Summer",simflags="-alarm=400 -emit_protected -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.08.21 19:29 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/08/2017 Continuing Simulation at 01/08/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/15/2017 Continuing Simulation at 01/15/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/22/2017 Continuing Simulation at 01/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/29/2017 Continuing Simulation at 01/29/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/05/2017 Continuing Simulation at 02/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/12/2017 Continuing Simulation at 02/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/19/2017 Continuing Simulation at 02/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/26/2017 Continuing Simulation at 02/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/05/2017 Continuing Simulation at 03/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/12/2017 Continuing Simulation at 03/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/19/2017 Continuing Simulation at 03/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/26/2017 Continuing Simulation at 03/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/02/2017 Continuing Simulation at 04/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/09/2017 Continuing Simulation at 04/09/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/16/2017 Continuing Simulation at 04/16/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/23/2017 Continuing Simulation at 04/23/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/30/2017 Continuing Simulation at 04/30/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/07/2017 Continuing Simulation at 05/07/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/14/2017 Continuing Simulation at 05/14/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/21/2017 Continuing Simulation at 05/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/28/2017 Continuing Simulation at 05/28/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/04/2017 Continuing Simulation at 06/04/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/11/2017 Continuing Simulation at 06/11/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/18/2017 Continuing Simulation at 06/18/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/25/2017 Continuing Simulation at 06/25/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/02/2017 Continuing Simulation at 07/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/09/2017 Continuing Simulation at 07/09/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16848000.000001 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -2.83344e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 16848000.000001 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.14938e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848006.970578 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -5.90841e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848006.970578 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -3.98546e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848006.970578 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -4.47895e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848006.970578 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -3.98546e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848006.970578 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -4.47895e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Sensors/VolumeFlowRate.mo:19:3-25:24:writable] | | | | The following assertion has been violated at time 16848042.523870 | | | | ((hvac.VOut1.V_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -9.87662e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16870514.755178 | | | | ((hvac.conVAV[2].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 16916463.431440 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -2.91611e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916505.955311 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -1.78238e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 16916505.955311 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -4.17854e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 16916505.955311 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -1.23352e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916580.000169 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.5529e-48" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916580.000169 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -6.22372e-50" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[1].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[1].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[3].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[3].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[4].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[4].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[5].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16956300.000170 | | | | ((hvac.conVAV[5].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 16965360.058341 | | | | ((hvac.conVAV[2].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." Updating Shadowing Calculations, Start Date=07/16/2017 Continuing Simulation at 07/16/2017 for SPAWN-RUNPERIOD LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 1279 state events LOG_STATS | info | | 3601 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 98392 steps taken LOG_STATS | info | | 125269 calls of functionODE LOG_STATS | info | | 61291 evaluations of jacobian LOG_STATS | info | | 1108 error test failures LOG_STATS | info | | 18 convergence test failures LOG_STATS | info | | 69289890 linear system solves LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 02min 24.10sec EnergyPlus Completed Successfully.