startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|T2Set.y|con.T2Sup.T|con.T2Ret.T|T1Sup.T|T1Ret.T|con.val.y_actual|pum.m_flow|con.pum.m_flow|con.res3.m_flow|mPum_flow_nominal|con.mPum_flow_nominal|fraLoa.y.1.|fraLoa.y.2.|loa.yLoa_actual|loa1.yLoa_actual|loa.con.val.y_actual|loa1.con.val.y_actual|dp1SetVal.y|dp1.p_rel|dp2SetVal.y|dp2.p_rel|pum.y_actual|con.pum.y_actual|TSupOpe.T|TRetOpe.T|loaOpe.yLoa_actual",fileNamePrefix="Buildings_11_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn",simflags="-alarm=400 -emit_protected -lv LOG_STATS") LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 36391.680000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.39595e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -9.68156e-32" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -1.96395e-33" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.eff.yMot, has value: -6.02691e-32" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.etaHyd, has value: -8.78314e-31" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 8 state events LOG_STATS | info | | 4 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 3186 steps taken LOG_STATS | info | | 4280 calls of functionODE LOG_STATS | info | | 430 evaluations of jacobian LOG_STATS | info | | 156 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 1 linear system solves LOG_SUCCESS | info | The simulation finished successfully.