startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Validation.Controller,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|duaDucCon.TZon|duaDucCon.TCooSet|duaDucCon.THeaSet|duaDucCon.TDis|duaDucCon.TColSup|duaDucCon.THotSup|duaDucCon.u1Win|duaDucCon.u1Occ|duaDucCon.uOpeMod|duaDucCon.ppmCO2|duaDucCon.VDis_flow|duaDucCon.oveFloSet|duaDucCon.oveCooDamPos|duaDucCon.oveHeaDamPos|duaDucCon.u1CooAHU|duaDucCon.u1HeaAHU|duaDucCon.VSet_flow|duaDucCon.yCooDam|duaDucCon.yHeaDam|duaDucCon.yZonCooTemResReq|duaDucCon.yColDucPreResReq|duaDucCon.yLowFloAla|duaDucCon.yFloSenAla|duaDucCon.yLeaDamAla",fileNamePrefix="Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Validation.Controller",simflags="-alarm=400 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel7.y)) --> "Warning: the cold-duct or hot-dcut damper is leaking." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel6.y)) --> "Warning: airflow sensor should be calibrated." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 20900.000004 | | | | ((duaDucCon.ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 20900.000004 | | | | ((duaDucCon.ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 63 state events LOG_STATS | info | | 724 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 11286 steps taken LOG_STATS | info | | 12983 calls of functionODE LOG_STATS | info | | 9709 evaluations of jacobian LOG_STATS | info | | 50 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.