startTime=0 stopTime=11000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4.4 wasm-jit simulation: simulate(BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile,startTime=0,stopTime=11000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile",simflags="-alarm=480 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Technologies/ThermalStorages/BaseClasses/BuoyancyModels/Buoyancy1.mo:11:3-12:165:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "The number of nodes used nEle is out of the validated range (between 4 and 40), see Info section of the selected buoyancy model." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senTem_bottom.warnAboutOnePortConnection)) --> "Sensor FluidStorageChargeDischargeProfile.senTem_bottom can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in FluidStorageChargeDischargeProfile.senTem_bottom." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 8 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 515 steps taken LOG_STATS | info | | 725 calls of functionODE LOG_STATS | info | | 174 evaluations of jacobian LOG_STATS | info | | 24 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.