startTime=1.0368e+07 stopTime=1.07136e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=138.24 wasm-jit simulation: simulate(BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage,startTime=1.0368e+07,stopTime=1.07136e+07,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage",simflags="-alarm=480 -lv LOG_STATS") LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not senTem1.warnAboutOnePortConnection)) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 10368552.960000 | | | | ((HX.m1_flow >= 0.0 and HX.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= HX.m1_flow <= 1e5, has value: -1.90169e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 10369658.880000 | | | | ((weatherData.weatherData.phiAir >= 0.0 and weatherData.weatherData.phiAir <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= weatherData.weatherData.phiAir <= 1.0, has value: 1.00005" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/WeatherData/WeatherDataReader.mo:57:3-63:84:writable] | | | | The following assertion has been violated at time 10492277.760000 | | | | ((weatherData.cloudCover >= 0.0 and weatherData.cloudCover <= 8.0)) --> "Variable violating min/max constraint: 0.0 <= weatherData.cloudCover <= 8.0, has value: 8.01774" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 43 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 6112 steps taken LOG_STATS | info | | 8237 calls of functionODE LOG_STATS | info | | 859 evaluations of jacobian LOG_STATS | info | | 144 error test failures LOG_STATS | info | | 4 convergence test failures LOG_STATS | info | | 3957481 linear system solves LOG_SUCCESS | info | The simulation finished successfully.