Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0003544/0.0003544, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0004636/0.0004636, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.3963/0.3963, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Data/Case600Results.mo:4:46-4:57:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 20552400000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Data/Case600Results.mo:5:46-5:57:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 15465600000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Data/Case600Results.mo:6:47-6:58:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 26200800000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Data/Case600Results.mo:7:47-7:58:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 22093200000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Case900.mo:7:15-7:25:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 7347600000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Case900.mo:8:15-8:25:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 4212000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Case900.mo:9:16-9:27:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 11394000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/ThermalZones/ISO13790/Validation/BESTEST/Case900.mo:10:16-10:26:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 7686000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/Systems/HVAC/Production/WoodHeating/Logs/LogStove.mo:74:18-74:29:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 51300000000 into a real [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo): time 0.255/0.255, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:44:3-56:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:58:3-65:19:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:67:3-72:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:74:3-79:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package BuildSysPro with version 3.6.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: simulate(BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=1051200,outputFormat="empty",variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled",simflags="-alarm=480 -lv LOG_STATS") simulate(BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=1051200,outputFormat="empty",variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled",simflags="-alarm=480 -lv LOG_STATS") [Timeout 1140] OMC exited with status 134 while running: simulate(BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=1051200,outputFormat="empty",variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled",simflags="-alarm=480 -lv LOG_STATS") Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.4ab24179585d4535ad0121ef8505d05f Nonlinear iteration variables with default zero start attribute in NLSJac1. (1) ======================================== 1: meteofile.G[3]:VARIABLE(flow=false ) "Output data {DIFH, DIRN, DIRH, GLOH, t0, CosDir[1:3], Solar azimuth angle , Solar elevation angle}" type: Real [10] Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with default zero start attribute in NLSJac12. (1) ======================================== 1: meteofile.G[3]:VARIABLE(flow=false ) "Output data {DIFH, DIRN, DIRH, GLOH, t0, CosDir[1:3], Solar azimuth angle , Solar elevation angle}" type: Real [10] Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Aborted (core dumped) [Calling os._exit(0), Time elapsed: 182.4150956249996]