startTime=0 stopTime=800 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.32 wasm-jit simulation: simulate(AixLib.Systems.HydraulicModules.Examples.Injection,startTime=0,stopTime=800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Systems.HydraulicModules.Examples.Injection",simflags="-alarm=480 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6:3-7:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.powEu.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7:3-8:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eta, has value: -1.43481e-33" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.heaDis.etaHyd, has value: -1.20322e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Injection.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.yMot, has value: -1.60051e-35" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 683.520000 | | | | ((Injection.valve.res3.y >= 0.0 and Injection.valve.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= Injection.valve.res3.y <= 1.0, has value: -2.28982e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 683.520000 | | | | ((Injection.valve.actPos.y >= 0.0 and Injection.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= Injection.valve.actPos.y <= 1.0, has value: 1" LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 283 steps taken LOG_STATS | info | | 442 calls of functionODE LOG_STATS | info | | 68 evaluations of jacobian LOG_STATS | info | | 7 error test failures LOG_STATS | info | | 3 convergence test failures LOG_STATS | info | | 64261 linear system solves LOG_SUCCESS | info | The simulation finished successfully.