startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=1440 stepSize=60 wasm-jit simulation: simulate(AixLib.Obsolete.Year2021.Fluid.Examples.PumpRadiatorValve,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=1440,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Obsolete.Year2021.Fluid.Examples.PumpRadiatorValve",simflags="-alarm=480 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 406 steps taken LOG_STATS | info | | 652 calls of functionODE LOG_STATS | info | | 50 evaluations of jacobian LOG_STATS | info | | 12 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0 linear system solves LOG_SUCCESS | info | The simulation finished successfully.