startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=3600 stepSize=2 wasm-jit simulation: simulate(AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.DynamicValidation,startTime=0,stopTime=7200,tolerance=1e-06,numberOfIntervals=3600,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.DynamicValidation",simflags="-alarm=480 -lv LOG_STATS") LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationEta.txt" LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationOda.txt" LOG_STDOUT | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationResult.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DynamicValidation.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DynamicValidation.fan1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | events LOG_STATS | info | | 676 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl-events LOG_STATS | info | | 15255 steps taken LOG_STATS | info | | 31295 calls of functionODE LOG_STATS | info | | 10016 evaluations of jacobian LOG_STATS | info | | 775 error test failures LOG_STATS | info | | 1982 convergence test failures LOG_STATS | info | | 12884625 linear system solves LOG_SUCCESS | info | The simulation finished successfully.