startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=1000 stepSize=7.2 wasm artifact (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner,startTime=0,stopTime=7200,tolerance=1e-06,numberOfIntervals=1000,outputFormat="empty",variableFilter="",fileNamePrefix="TAeZoSysPro_TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner",simflags=" -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=7200 -tolerance=1e-06 -stepSize=7.2 -noemit -s fmi3:me",resimulateExecutable="TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.1 ms (model kernel linked against the cached adapter, 0.5 MB) LOG_STDOUT | info | iteration to converge on Fview: 8 TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:21: the Rayleigh number > 10^12 is out of the range of the correlation TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:49: the Rayleigh number >1.5*10^9 is out of the range of the correlation TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:54: the Rayleigh number >10^9 is out of the range of the correlation TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:48: the Rayleigh number >1.5*10^9 is out of the range of the correlation TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20: the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/BasesClasses/FreeConvection_dT_decoupled.mo:20: Variable violating min/max constraint: 273.15 <= wood_burner.convection_emitter.T_mean <= 373.15, has value: 563.628 LOG_STDOUT | info | ModelExchange instantiated in 120.0 ms LOG_STDOUT | info | ModelExchange run: 164 steps, 3189 evaluations, 41 Jacobians, 0 state events, 0 time events, 1001 samples in 102.9 ms LOG_SUCCESS | info | The simulation finished successfully.