Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IDEAS_dev_IDEAS.Airflow.AHU.Validation.AdsolairDatasheetSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0005772/0.0005772, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0005199/0.0005199, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.3512/0.3512, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Examples/PPD12/Structure.mo:531:21-535:34:writable] Warning: Lexer treating \\ as \\\\, since \\e is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Examples/PPD12/Structure.mo:531:21-535:42:writable] Warning: Lexer treating \\ as \\\\, since \\< is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/package.mo): time 0.3433/0.3433, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Utilities/Cryptographics/BaseClasses/sha.mo:2:1-19:8:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Utilities/File/sha2.mo:2:1-9:9:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 179] Using package IDEAS with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IDEAS.Airflow.AHU.Validation.AdsolairDatasheetSummer,fileNamePrefix="IDEAS_dev_IDEAS_Airflow_AHU_Validation_AdsolairDatasheetSummer",fmuType="me_cs",version="3.0",platforms={"wasm"}) "" <> buildModelFMU(IDEAS.Airflow.AHU.Validation.AdsolairDatasheetSummer,fileNamePrefix="IDEAS_dev_IDEAS_Airflow_AHU_Validation_AdsolairDatasheetSummer",fmuType="me_cs",version="3.0",platforms={"wasm"}) [Timeout 660] OMC exited with status 134 while running: "" <> buildModelFMU(IDEAS.Airflow.AHU.Validation.AdsolairDatasheetSummer,fileNamePrefix="IDEAS_dev_IDEAS_Airflow_AHU_Validation_AdsolairDatasheetSummer",fmuType="me_cs",version="3.0",platforms={"wasm"}) Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.ece9e952fe0241fda7f450830db41bee Nonlinear iteration variables with predefined start attribute in NLSJac8. (1) ======================================== 1: adsolair58.IEH.wetBulOut.TWetBul:VARIABLE(flow=false min = 1.0 max = 1e4 start = 293.0 unit = "K" nominal = 300.0 protected = true ) "Wet bulb temperature" type: Real Linear iteration variables with predefined start attributes that are unrelevant in NLSJac8. (1) ======================================== 1: adsolair58.IEH.wetBulOut.XiSatOut:VARIABLE(min = 0.0 max = 1.0 start = 0.01 nominal = 0.01 protected = true ) "Water vapor mass fraction at saturation" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with predefined start attribute in NLSJac9. (1) ======================================== 1: adsolair58.IEH.wetBulIn.TWetBul:VARIABLE(flow=false min = 1.0 max = 1e4 start = 293.0 unit = "K" nominal = 300.0 protected = true ) "Wet bulb temperature" type: Real Linear iteration variables with predefined start attributes that are unrelevant in NLSJac9. (1) ======================================== 1: adsolair58.IEH.wetBulIn.XiSatOut:VARIABLE(min = 0.0 max = 1.0 start = 0.01 nominal = 0.01 protected = true ) "Water vapor mass fraction at saturation" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with predefined start attribute in NLSJac12. (1) ======================================== 1: adsolair58.IEH.wetBulIn.TWetBul:VARIABLE(flow=false min = 1.0 max = 1e4 start = 293.0 unit = "K" nominal = 300.0 protected = true ) "Wet bulb temperature" type: Real Linear iteration variables with predefined start attributes that are unrelevant in NLSJac12. (1) ======================================== 1: adsolair58.IEH.wetBulIn.XiSatOut:VARIABLE(min = 0.0 max = 1.0 start = 0.01 nominal = 0.01 protected = true ) "Water vapor mass fraction at saturation" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") Nonlinear iteration variables with predefined start attribute in NLSJac15. (1) ======================================== 1: adsolair58.IEH.wetBulOut.TWetBul:VARIABLE(flow=false min = 1.0 max = 1e4 start = 293.0 unit = "K" nominal = 300.0 protected = true ) "Wet bulb temperature" type: Real Linear iteration variables with predefined start attributes that are unrelevant in NLSJac15. (1) ======================================== 1: adsolair58.IEH.wetBulOut.XiSatOut:VARIABLE(min = 0.0 max = 1.0 start = 0.01 nominal = 0.01 protected = true ) "Water vapor mass fraction at saturation" type: Real Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->Additional Translation Flags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") thread 'omc-main' (260853) has overflowed its stack fatal runtime error: stack overflow, aborting Aborted (core dumped) [Calling os._exit(0), Time elapsed: 6.523893640958704]