startTime=0 stopTime=30000 tolerance=1e-06 numberOfIntervals=2500 stepSize=12 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater,startTime=0,stopTime=30000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="Time|desuperheater_1.shell.h|desuperheater_1.shell.p|desuperheater_1.tubes.h|desuperheater_1.tubes.p|desuperheater_1.wall.T_w_a|desuperheater_1.wall.T_w_i|desuperheater_2.shell.h|desuperheater_2.shell.p|desuperheater_2.tubes.h|desuperheater_2.tubes.p|desuperheater_2.wall.T_w_a|desuperheater_2.wall.T_w_i",fileNamePrefix="ClaRa_dev_ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -startTime=0 -stopTime=30000 -tolerance=1e-06 -stepSize=12 -variableFilter=Time|desuperheater_1.shell.h|desuperheater_1.shell.p|desuperheater_1.tubes.h|desuperheater_1.tubes.p|desuperheater_1.wall.T_w_a|desuperheater_1.wall.T_w_i|desuperheater_2.shell.h|desuperheater_2.shell.p|desuperheater_2.tubes.h|desuperheater_2.tubes.p|desuperheater_2.wall.T_w_a|desuperheater_2.wall.T_w_i -r=../ClaRa_dev_ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater_res.mat -s fmi3:me",resimulateExecutable="../ClaRa_dev_ClaRa_Components_HeatExchangers_Check_EvaluateDesuperheater.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.6 ms (model kernel linked against the cached adapter, 1.2 MB) ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/CharLine_L2.mo:57: Variable violating min constraint: 0.0 <= desuperheater_1.tubes.heattransfer.Delta_T_wi, has value: -143.126 ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/CharLine_L2.mo:58: Variable violating min constraint: 0.0 <= desuperheater_1.tubes.heattransfer.Delta_T_wo, has value: -208.97 ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/CharLine_L2.mo:59: Variable violating min constraint: 0.0 <= desuperheater_1.tubes.heattransfer.Delta_T_mean, has value: -173.976 ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/CharLine_L2.mo:61: Variable violating min constraint: 0.0 <= desuperheater_1.tubes.heattransfer.Delta_T_U, has value: -208.97 ClaRa.Components.HeatExchangers.Check.EvaluateDesuperheater: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/CharLine_L2.mo:62: Variable violating min constraint: 0.0 <= desuperheater_1.tubes.heattransfer.Delta_T_L, has value: -143.126 LOG_STDOUT | info | ModelExchange instantiated in 449.2 ms LOG_STDOUT | info | ModelExchange run: 7375 steps, 24151 evaluations, 2669 Jacobians, 0 state events, 100 time events, 2701 samples in 1485.1 ms LOG_SUCCESS | info | The simulation finished successfully.