startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Templates.Components.Validation.Coils,startTime=0,stopTime=200,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Templates.Components.Validation.Coils",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=200 -tolerance=1e-06 -stepSize=0.08 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Templates_Components_Validation_Coils.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.3 ms (model kernel linked against the cached adapter, 1.9 MB) Buildings.Templates.Components.Validation.Coils: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: *** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.245016, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 4.5312 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00546923 - 0.0059222 = -0.000452973 QLat_flow_nominal = -16760.9 Buildings.Templates.Components.Validation.Coils: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: *** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.310206, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 1.1328 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00527094 - 0.00592132 = -0.000650382 QLat_flow_nominal = -4752.01 Buildings.Templates.Components.Validation.Coils: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121: *** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 50. stage = 1 TEvaInMin = 290.37 Kelvin (17.22 degC) TEvaIn = 286.457 Kelvin (13.3068 degC) TEvaInMax = 294.82 Kelvin (21.67 degC) Extrapolation can introduce large errors. This warning will only be reported once for each stage. Buildings.Templates.Components.Validation.Coils: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121: *** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 100. stage = 2 TEvaInMin = 290.37 Kelvin (17.22 degC) TEvaIn = 286.457 Kelvin (13.3068 degC) TEvaInMax = 294.82 Kelvin (21.67 degC) Extrapolation can introduce large errors. This warning will only be reported once for each stage. LOG_STDOUT | info | ModelExchange instantiated in 837.3 ms LOG_STDOUT | info | ModelExchange run: 221 steps, 507 evaluations, 89 Jacobians, 1 state events, 4 time events, 2511 samples in 78.4 ms LOG_SUCCESS | info | The simulation finished successfully.