startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=86400 -tolerance=1e-06 -stepSize=34.56 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_DecouplingTemperature.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.9 ms (model kernel linked against the cached adapter, 2.9 MB) Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -4.22339e-38 Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46: Variable violating min constraint: 0.0 <= con.pum.pumSpe.heaDis.etaHyd, has value: -1.90291e-34 Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68: Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -2.39029e-31 Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68: Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -2.37985e-31 LOG_STDOUT | info | ModelExchange instantiated in 2164.7 ms LOG_STDOUT | info | ModelExchange run: 2978 steps, 13324 evaluations, 703 Jacobians, 0 state events, 12 time events, 2525 samples in 356.0 ms LOG_SUCCESS | info | The simulation finished successfully.