startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuningFailure,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuningFailure",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=3600 -tolerance=1e-06 -stepSize=1.44 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuningFailure.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.3 ms (model kernel linked against the cached adapter, 0.9 MB) Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuningFailure: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12: Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOnRec.yRec.y, has value: 0 Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuningFailure: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12: Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOffRec.yRec.y, has value: 0 Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuningFailure: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Autotuning failed. The controller gains are unchanged. Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuningFailure: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: The asymmetry level of the relay controller is lower than the half period ratio. Increase the asymmetry level. LOG_STDOUT | info | ModelExchange instantiated in 3.8 ms LOG_STDOUT | info | ModelExchange run: 4019 steps, 17726 evaluations, 1278 Jacobians, 15 state events, 15 time events, 2561 samples in 104.9 ms LOG_SUCCESS | info | The simulation finished successfully.