startTime=0 stopTime=1.54656e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=6186.24 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100,startTime=0,stopTime=1.54656e+07,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=1.54656e+07 -tolerance=1e-06 -stepSize=6186.24 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRatePulse100.fmu") LOG_STDOUT | info | wasm artifact loaded in 2.0 ms (model kernel linked against the cached adapter, 14.1 MB) LOG_STDOUT | info | ModelExchange instantiated in 3679.4 ms LOG_STDOUT | info | ModelExchange run: 68755 steps, 1219851 evaluations, 45298 Jacobians, 0 state events, 4859 time events, 12219 samples in 32218.3 ms LOG_SUCCESS | info | The simulation finished successfully.