startTime=1.58112e+07 stopTime=1.6416e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling,startTime=1.58112e+07,stopTime=1.6416e+07,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=1.58112e+07 -stopTime=1.6416e+07 -tolerance=1e-06 -stepSize=241.92 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Fluid_DXSystems_Cooling_AirSource_Examples_SpaceCooling.fmu") LOG_STDOUT | info | wasm artifact loaded in 1.8 ms (model kernel linked against the cached adapter, 2.8 MB) Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: *** Warning in SpaceCooling.fan: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: *** Warning in SpaceCooling.fan1: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: *** Warning in SpaceCooling.fan2: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: *** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.52681, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 0.646123 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 QLat_flow_nominal = -2694 Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: *** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.52681, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 0.646123 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 QLat_flow_nominal = -2694 Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: *** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.52681, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 0.646123 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 QLat_flow_nominal = -2694 Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121: *** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 1.58491e+07. stage = 1 TEvaInMin = 285.928 Kelvin (12.7778 degC) TEvaIn = 297.06 Kelvin (23.9098 degC) TEvaInMax = 297.039 Kelvin (23.8889 degC) Extrapolation can introduce large errors. This warning will only be reported once for each stage. LOG_STDOUT | info | ModelExchange instantiated in 1110.5 ms LOG_STDOUT | info | ModelExchange run: 127669 steps, 437902 evaluations, 34340 Jacobians, 2356 state events, 0 time events, 7213 samples in 15177.9 ms LOG_SUCCESS | info | The simulation finished successfully.