startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Examples.FanCoils.FourPipe,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Examples.FanCoils.FourPipe",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=86400 -tolerance=1e-06 -stepSize=34.56 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Examples_FanCoils_FourPipe.fmu") LOG_STDOUT | info | wasm artifact loaded in 2.9 ms (model kernel linked against the cached adapter, 9.7 MB) Buildings.Examples.FanCoils.FourPipe: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68: Variable violating min/max constraint: 0.0 <= fanCoiUni2.hexWetNtu.SHR <= 1.0, has value: -8.75403e-16 Buildings.Examples.FanCoils.FourPipe: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: Variable violating min constraint: 0.0 <= fanCoiUni2.fan.etaHyd, has value: -3.37625e-19 Buildings.Examples.FanCoils.FourPipe: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46: Variable violating min constraint: 0.0 <= fanCoiUni2.fan.heaDis.etaHyd, has value: -6.04163e-16 Buildings.Examples.FanCoils.FourPipe: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68: Variable violating min/max constraint: 0.0 <= fanCoiUni3.hexWetNtu.SHR <= 1.0, has value: -8.07558e-16 Buildings.Examples.FanCoils.FourPipe: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: Variable violating min constraint: 0.0 <= fanCoiUni3.fan.etaHyd, has value: -3.37625e-19 Buildings.Examples.FanCoils.FourPipe: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46: Variable violating min constraint: 0.0 <= fanCoiUni3.fan.heaDis.etaHyd, has value: -6.04163e-16 LOG_STDOUT | info | ModelExchange instantiated in 6361.6 ms LOG_STDOUT | info | ModelExchange run: 8182 steps, 169283 evaluations, 8054 Jacobians, 35 state events, 18 time events, 2607 samples in 5030.1 ms LOG_SUCCESS | info | The simulation finished successfully.