startTime=1.0368e+07 stopTime=1.05408e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass,startTime=1.0368e+07,stopTime=1.05408e+07,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=1.0368e+07 -stopTime=1.05408e+07 -tolerance=1e-06 -stepSize=69.12 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.9 ms (model kernel linked against the cached adapter, 0.9 MB) Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: Variable violating min/max constraint: -0.1 <= tow.cooTowSys.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344 Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[2].dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344 Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[2].per.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344 Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[1].dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344 Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[1].per.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344 LOG_STDOUT | info | ModelExchange instantiated in 1202.1 ms LOG_STDOUT | info | ModelExchange run: 15494 steps, 40531 evaluations, 2848 Jacobians, 158 state events, 0 time events, 2817 samples in 610.1 ms LOG_SUCCESS | info | The simulation finished successfully.