startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.88 wasm FMU (me: FMI 3.0 Model Exchange, integrated by omc with the model's own solver (DASKR unless its annotation says otherwise; IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms,startTime=0,stopTime=7200,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=7200 -tolerance=1e-06 -stepSize=2.88 -noemit -s fmi3:me",resimulateExecutable="../Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.1 ms (model kernel linked against the cached adapter, 0.1 MB) Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: fan has been commanded ON but still OFF. Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: discharge air temperature is 8 degC less than the setpoint. Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: airflow is less than 70% of the setpoint. Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: airflow is less than 50% of the setpoint. Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: fan has been commanded OFF but still ON. Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: the damper is leaking. Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: Warning: airflow sensor should be calibrated. LOG_STDOUT | info | ModelExchange instantiated in 2.1 ms LOG_STDOUT | info | ModelExchange run: 2517 steps, 2517 evaluations, 0 Jacobians, 5 state events, 14 time events, 2539 samples in 19.6 ms LOG_SUCCESS | info | The simulation finished successfully.