startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.001 wasm artifact (cs: FMI 3.0 Co-Simulation, the artifact integrating itself with DASKR): simulate(ThermofluidStream.Processes.Tests.ConductionElement,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=1000,outputFormat="mat",variableFilter="Time|conductionElement.h|conductionElement1.deltaE_system|conductionElement1.h|conductionElement1.inlet.m_flow|conductionElement2.h|conductionElement2.inlet.m_flow|conductionElement3.deltaE_system|conductionElement3.h|conductionElement4.h|sink.inlet.m_flow|source1.outlet.m_flow|source2.outlet.m_flow",fileNamePrefix="ThermofluidStream_ThermofluidStream.Processes.Tests.ConductionElement",simflags=" -alarm=240 -emit_protected -lv LOG_STATS -startTime=0 -stopTime=1 -tolerance=1e-06 -stepSize=0.001 -r=ThermofluidStream_ThermofluidStream.Processes.Tests.ConductionElement_cs_res.mat -s fmi3:cs",resimulateExecutable="ThermofluidStream_ThermofluidStream_Processes_Tests_ConductionElement.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.1 ms (model kernel linked against the cached adapter, 0.2 MB) LOG_STDOUT | info | CoSimulation instantiated in 0.4 ms LOG_STDOUT | info | CoSimulation run: 1002 communication steps, 2 events, 2 early returns, 1005 samples in 58.7 ms LOG_SUCCESS | info | The simulation finished successfully.