Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_ThermofluidStream.Boundaries.Tests.TankOverfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0005025/0.0005025, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0004313/0.0004313, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.3409/0.3409, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/package.mo): time 0.2206/0.2206, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package ThermofluidStream with version 1.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankOverfilling,fileNamePrefix="ThermofluidStream_ThermofluidStream_Boundaries_Tests_TankOverfilling",fmuType="me_cs",version="3.0",platforms={"wasm"}) "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankOverfilling,fileNamePrefix="ThermofluidStream_ThermofluidStream_Boundaries_Tests_TankOverfilling",fmuType="me_cs",version="3.0",platforms={"wasm"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 2.905e-06/2.905e-06, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 1.707e-05/1.998e-05, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instantiate(ThermofluidStream.Boundaries.Tests.TankOverfilling): time 0.5478/0.5478, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instExpressions: time 0.01502/0.5628, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.updateImplicitVariability: time 0.001233/0.5641, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeComponents: time 0.003703/0.5678, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeBindings: time 0.01586/0.5836, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.001808/0.5854, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 1.9631060910178348]