startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 wasm FMU (cs: FMI 3.0 Co-Simulation, the FMU integrating itself with DASKR): simulate(Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl,startTime=0,stopTime=604800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_13_Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS -startTime=0 -stopTime=604800 -tolerance=1e-06 -stepSize=241.92 -noemit -s fmi3:cs",resimulateExecutable="../Buildings_13_Buildings_DHC_Examples_Combined_SeriesVariableFlowAgentControl.fmu") Simulation execution failed for model: Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl LOG_STDOUT | info | wasm artifact loaded in 7.0 ms (model kernel linked against the cached adapter, 20.0 MB) Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/ConservationEquation.mo:128: Variable violating min/max constraint: -1e8 <= bui[3].ets.volMix_b.dynBal.ports_H_flow[1] <= 1e8, has value: 5.40276e+09 Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/ConservationEquation.mo:128: Variable violating min/max constraint: -1e8 <= bui[3].ets.volMix_b.dynBal.ports_H_flow[4] <= 1e8, has value: -5.40504e+09 Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/ConservationEquation.mo:128: Variable violating min/max constraint: -1e8 <= dis.con[3].junConSup.vol.dynBal.ports_H_flow[2] <= 1e8, has value: 5.39462e+09 Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/ConservationEquation.mo:128: Variable violating min/max constraint: -1e8 <= dis.con[3].junConSup.vol.dynBal.ports_H_flow[3] <= 1e8, has value: -5.40276e+09 Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl: logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/ConservationEquation.mo:128: Variable violating min/max constraint: -1e8 <= dis.con[3].junConRet.vol.dynBal.ports_H_flow[1] <= 1e8, has value: -5.39462e+09 LOG_ASSERT | debug | Solving non-linear system 18828 failed at time=5.7320319944704e-06. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 18828 failed at time=5.71547290592818e-06. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | Integrator attempt to handle a problem with a called assert. LOG_ERROR | error | fmi3DoStep returned error