Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.AirHandlersFans.Validation.VAVMultiZone.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real [:1:1-1:33:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0004621/0.0004621, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0004366/0.0004366, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.35/0.35, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/package.mo): time 0.7416/0.7416, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 179] Using package Buildings with version 12.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Templates.AirHandlersFans.Validation.VAVMultiZone,fileNamePrefix="Buildings_12_Buildings_Templates_AirHandlersFans_Validation_VAVMultiZone",fmuType="me_cs",version="3.0",platforms={"wasm"}) "" <> buildModelFMU(Buildings.Templates.AirHandlersFans.Validation.VAVMultiZone,fileNamePrefix="Buildings_12_Buildings_Templates_AirHandlersFans_Validation_VAVMultiZone",fmuType="me_cs",version="3.0",platforms={"wasm"}) [Timeout 300] "Notification: Performance of FrontEnd - loaded program: time 1.103e-06/1.103e-06, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 1.742e-05/1.853e-05, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Templates/AirHandlersFans/Validation/UserProject/Data/AllSystems.mo:9:3-63:55:writable] Warning: Components are deprecated in class. Notification: Performance of NFInst.instantiate(Buildings.Templates.AirHandlersFans.Validation.VAVMultiZone): time 2.575/2.575, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instExpressions: time 0.7028/3.278, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.updateImplicitVariability: time 0.07745/3.355, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeComponents: time 0.08244/3.438, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeBindings: time 0.1339/3.572, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeClassSections: time 0.09983/3.672, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Templates/Data/AllSystems.mo:16:3-20:96:writable] Warning: Parameter datAll.tit24CliZon has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Controls.OBC.ASHRAE.G36.Types.Title24ClimateZone.Zone_1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Templates/Components/Data/Coil.mo:111:3-117:80:writable] Warning: Parameter datAll.VAV_1.coiHeaPre.wAirEnt_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Templates/Components/Data/Coil.mo:111:3-117:80:writable] Warning: Parameter datAll.VAV_1.coiHeaReh.wAirEnt_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Templates/AirHandlersFans/Components/Data/OutdoorReliefReturnSection.mo:23:3-27:49:writable] Warning: Parameter VAV_1.secOutRel.dat.nFanRet has no value, and is fixed during initialization (fixed=true), using available start value (start=if VAV_1.secOutRel.dat.typFanRet == Buildings.Templates.Components.Types.Fan.None then 0 else 1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Templates/AirHandlersFans/Components/Data/OutdoorReliefReturnSection.mo:28:3-32:49:writable] Warning: Parameter VAV_1.secOutRel.dat.nFanRel has no value, and is fixed during initialization (fixed=true), using available start value (start=if VAV_1.secOutRel.dat.typFanRel == Buildings.Templates.Components.Types.Fan.None then 0 else 1) as default value. Notification: Performance of NFFlatten.flatten: time 0.1882/3.86, allocations: 0 / 0, free: 0 / 0 [NFFrontEnd/NFConnection.mo:0:0-0:0:writable] Error: Internal error NFConnection.checkBalance got unbalanced connection connect(sigBAS.ppmCO2Set.y, sigBAS.busTer.ppmCO2Set): lhs: {sigBAS.ppmCO2Set[1].y, sigBAS.ppmCO2Set[2].y} rhs: {sigBAS.busTer[1].ppmCO2Set[1], sigBAS.busTer[1].ppmCO2Set[2], sigBAS.busTer[2].ppmCO2Set[1], sigBAS.busTer[2].ppmCO2Set[2]} Notification: Performance of FrontEnd: time 0.06817/3.928, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 296] [Calling sys.exit(0), Time elapsed: 6.025955016026273]