Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.01 Regular simulation: ./ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0635937s reading init.xml | | | | | | 0.00574876s reading info.xml | | | | | | 0.54433s [ 4.5%] pre-initialization | | | | | | 0.0114474s [ 0.1%] initialization | | | | | | 0.00326389s [ 0.0%] steps | | | | | | 0.00720821s [ 0.1%] solver (excl. callbacks) | | | | | | 0.0286408s [ 0.2%] creating output-file | | | | | | 0.000230043s [ 0.0%] event-handling | | | | | | 0.0155127s [ 0.1%] overhead | | | | | | 11.5773s [ 95.0%] simulation | | | | | | 12.188s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 299 steps taken | | | | | | 413 calls of functionODE | | | | | | 58 evaluations of jacobian | | | | | | 14 error test failures | | | | | | 0 convergence test failures | | | | | | 7.25257s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.