Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.TestTransient.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001283/0.001283, allocations: 80.44 kB / 19.18 MB, free: 2.527 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001442/0.001442, allocations: 166 kB / 22.46 MB, free: 5.355 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.239/1.239, allocations: 158.6 MB / 184.2 MB, free: 6.418 MB / 174.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo): time 0.1181/0.1181, allocations: 19.09 MB / 255.6 MB, free: 24 kB / 238.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/Utilities/LinProgFunc.mo:6:1-33:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package SolarTherm with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.TestTransient,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.TestTransient") translateModel(SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.TestTransient,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.TestTransient") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 4.879e-06/4.879e-06, allocations: 4 kB / 385.4 MB, free: 8.457 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 3.313e-05/3.801e-05, allocations: 2.281 kB / 385.4 MB, free: 8.453 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/Media/CO2/CO2_ph.mo:127:7-127:68:writable] Error: Invalid prefix outer on formal parameter tableIDh_p_T. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] Error: Class Medium.MassFlowRate not found in scope FluidPort. Notification: Performance of FrontEnd: time 0.01256/0.0126, allocations: 9.018 MB / 394.4 MB, free: 15.39 MB / 334.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.241413291543722] Failed to read output from testmodel.py, exit status != 0: 0.02081362158060074 0.034955724 -1.0 Calling exit ...