Environment - simulationEnvironment: startTime=0 stopTime=4e-06 tolerance=1e-08 numberOfIntervals=1999 stepSize=2.001e-09 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Electrical.TransmissionLine.ScaledExperiments.TransmissionLineEquations_N_10 -s=ida -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.000940133s reading init.xml | | | | | | 0.000171541s reading info.xml | | | | | | 0.000429726s [ 6.6%] pre-initialization | | | | | | 0.000239359s [ 3.7%] initialization | | | | | | 1.022e-06s [ 0.0%] steps | | | | | | 0.00251965s [ 38.7%] solver (excl. callbacks) | | | | | | 0.000787958s [ 12.1%] creating output-file | | | | | | 5.47594e-21s [ 0.0%] event-handling | | | | | | 0.00013969s [ 2.1%] overhead | | | | | | 0.00232917s [ 35.8%] simulation | | | | | | 0.00652493s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 1223 steps taken | | | | | | 1347 calls of functionODE | | | | | | 42 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000121681s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.