Environment - simulationEnvironment: startTime=0 stopTime=0.2 tolerance=1e-06 numberOfIntervals=2000 stepSize=0.0001 Regular simulation: ./Modelica_trunk_Modelica.Magnetic.FluxTubes.Examples.Hysteresis.ThreePhaseTransformerWithRectifier -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0116249s reading init.xml | | | | | | 0.000966443s reading info.xml | | | | | | 0.000502743s [ 0.0%] pre-initialization | | | | | | 0.000302076s [ 0.0%] initialization | | | | | | 0.0017183s [ 0.1%] steps | | | | | | 0.0979828s [ 5.2%] solver (excl. callbacks) | | | | | | 0.00170883s [ 0.1%] creating output-file | | | | | | 0.617784s [ 32.8%] event-handling | | | | | | 0.00333868s [ 0.2%] overhead | | | | | | 1.16069s [ 61.6%] simulation | | | | | | 1.88403s [100.0%] total | | | | | events | | | | | | 350 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 48351 steps taken | | | | | | 63423 calls of functionODE | | | | | | 5525 evaluations of jacobian | | | | | | 513 error test failures | | | | | | 298 convergence test failures | | | | | | 0.472256s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.