Environment - simulationEnvironment: startTime=1.5984e+07 stopTime=1.67616e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=311.04 Regular simulation: ./Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalSummer -abortSlowSimulation -alarm=800 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 15984000.000000 | | | | ((zonAHUOpt.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.132142" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 15984000.000000 | | | | ((zonAHUCon.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.132142" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 16135200.001614 | | | | ((zonAHUOpt.hvac.cooCoi.m1_flow >= 0.0 and zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5, has value: -1.43493e-42" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 16394400.001640 | | | | ((zonAHUCon.hvac.ideVal.preMasFlo.m_flow >= 0.0 and zonAHUCon.hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUCon.hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -7.17465e-43" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.606344s reading init.xml | | | | | | 0.0483226s reading info.xml | | | | | | 0.0227952s [ 0.1%] pre-initialization | | | | | | 0.070796s [ 0.4%] initialization | | | | | | 0.00127854s [ 0.0%] steps | | | | | | 0.33012s [ 1.9%] solver (excl. callbacks) | | | | | | 0.0711239s [ 0.4%] creating output-file | | | | | | 2.90468s [ 16.8%] event-handling | | | | | | 0.0556966s [ 0.3%] overhead | | | | | | 13.8651s [ 80.0%] simulation | | | | | | 17.3216s [100.0%] total | | | | | events | | | | | | 182 state events | | | | | | 10 time events | | | | | solver: dassl | | | | | | 11127 steps taken | | | | | | 16068 calls of functionODE | | | | | | 2901 evaluations of jacobian | | | | | | 787 error test failures | | | | | | 0 convergence test failures | | | | | | 10.9373s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.