Environment - simulationEnvironment: startTime=0 stopTime=2500 tolerance=1e-06 numberOfIntervals=2500 stepSize=1 Regular simulation: ./Buildings_12_Buildings.Fluid.HeatPumps.Examples.EquationFitReversible_CoolingClosedLoop -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.022646s reading init.xml | | | | | | 0.00228112s reading info.xml | | | | | | 0.00121959s [ 3.1%] pre-initialization | | | | | | 0.000394881s [ 1.0%] initialization | | | | | | 4.027e-06s [ 0.0%] steps | | | | | | 0.00505504s [ 13.0%] solver (excl. callbacks) | | | | | | 0.00248868s [ 6.4%] creating output-file | | | | | | 0.00117563s [ 3.0%] event-handling | | | | | | 0.00836776s [ 21.5%] overhead | | | | | | 0.0202299s [ 52.0%] simulation | | | | | | 0.0389355s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 25 time events | | | | | solver: dassl | | | | | | 2208 steps taken | | | | | | 3690 calls of functionODE | | | | | | 1237 evaluations of jacobian | | | | | | 196 error test failures | | | | | | 133 convergence test failures | | | | | | 0.00412195s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.