Environment - simulationEnvironment: startTime=4.4928e+06 stopTime=4.6656e+06 tolerance=1e-06 numberOfIntervals=192 stepSize=900 Regular simulation: ./Buildings_11_Buildings.Examples.VAVReheat.Validation.TraceSubstance -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000018. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 4492800.000018. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 4492926.041251 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -2.14442e-18" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 4492926.041251 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -2.13346e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 4496400.000000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -6.90271e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 4496400.000000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -1.07479e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 4496400.000000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -1.45517e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 4496400.000000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -1.38187e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 4496400.000000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -1.45517e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 4527900.000000 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -1.16285e-39" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 4527900.000000 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -5.00141e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 4527900.000000 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -1.37947e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 4562100.000000 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -9.01018e-50" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 4614300.000000 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -2.02008e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 4633200.000000 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: 1.00001" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 4648500.000000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.09664e-45" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 4648500.000000 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -6.92467e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 4648500.000000 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -1.66308e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 4648500.000000 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -1.17535e-26" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.545369s reading init.xml | | | | | | 0.0448411s reading info.xml | | | | | | 0.0156833s [ 0.0%] pre-initialization | | | | | | 0.0553734s [ 0.0%] initialization | | | | | | 5.18301s [ 4.5%] steps | | | | | | 5.38275s [ 4.7%] solver (excl. callbacks) | | | | | | 0.0242629s [ 0.0%] creating output-file | | | | | | 2.688s [ 2.3%] event-handling | | | | | | 0.00790146s [ 0.0%] overhead | | | | | | 102.38s [ 88.5%] simulation | | | | | | 115.737s [100.0%] total | | | | | events | | | | | | 43 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 17379 steps taken | | | | | | 33383 calls of functionODE | | | | | | 19333 evaluations of jacobian | | | | | | 316 error test failures | | | | | | 6075 convergence test failures | | | | | | 103.297s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.