/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling_OMSimulator_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling_OMSimulator_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling/model-4p25nsza" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.fmu - startTime: 0.000000 - stopTime: 1000.000000 - tolerance: 0.000001 - stepSize: 0.400000 info: maximum step size for 'model.root': 0.400000 info: Result file: ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling_OMSimulator_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.boundaryFore1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.boundaryFore1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.boundaryFore1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.boundaryFore1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.flowResistance2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.flowResistance5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.source1.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Undirected/Boundaries/TankCuboid.mo:58:3-58:107:writable] | | | | The following assertion has been violated at time 0.903659 | | | | ((tank1.V_liquid <= tank1.V_ref)) --> "Trying to fit more liquid into tank than it holds" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Undirected/Boundaries/Internal/PartialTankUndirected.mo:232:5-235:36:writable] | | | | The following assertion has been violated at time 1.200000 | | | | ((checkValve.inlet.m_flow > tank1.m_flow_assert)) --> "Negative massflow at tank inlet" info: Final Statistics for 'model.root': NumSteps = 2728 NumRhsEvals = 2867 NumLinSolvSetups = 165 NumNonlinSolvIters = 2866 NumNonlinSolvConvFails = 1 NumErrTestFails = 11 info: 2 warnings info: 0 errors