/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor/model-248gcavo" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.010000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((perfectGas.p_min >= 611.657 and perfectGas.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= perfectGas.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((idealGas.p_min >= 611.657 and idealGas.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= idealGas.p_min <= 1e8, has value: 100" info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.010000 info: Result file: ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.idealGas.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.idealGas.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.perfectGas.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.perfectGas.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor.source1.displayPos4 will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:54:3-56:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(idealGas.adiabaticModel.Z_in >= 0.9523809523809523) and noEvent(idealGas.adiabaticModel.Z_in <= 1.05))) --> "In "compressibilityFactor.idealGas.adiabaticModel" the inlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:57:3-59:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(idealGas.adiabaticModel.Z_out >= 0.9523809523809523) and noEvent(idealGas.adiabaticModel.Z_out <= 1.05))) --> "In "compressibilityFactor.idealGas.adiabaticModel" the outlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:54:3-56:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(perfectGas.adiabaticModel.Z_in >= 0.9523809523809523) and noEvent(perfectGas.adiabaticModel.Z_in <= 1.05))) --> "In "compressibilityFactor.perfectGas.adiabaticModel" the inlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:57:3-59:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(perfectGas.adiabaticModel.Z_out >= 0.9523809523809523) and noEvent(perfectGas.adiabaticModel.Z_out <= 1.05))) --> "In "compressibilityFactor.perfectGas.adiabaticModel" the outlet state deviates from ideal gas behaviour beyond the specified tolerance." info: Final Statistics for 'model.root': NumSteps = 101 NumRhsEvals = 102 NumLinSolvSetups = 6 NumNonlinSolvIters = 101 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors