/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.AdiabaticPerfectGas_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.AdiabaticPerfectGas" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.AdiabaticPerfectGas" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.AdiabaticPerfectGas/model-co14wu3t" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.AdiabaticPerfectGas" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.010000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Examples/TUMExercisesThermodynamicCycles/Exercise3OttoEngine/BaseModel.mo:10:3-10:87:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((T3 >= 273.15 and T3 <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= T3 <= 373.15, has value: 2200" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:18:3-21:146:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 2200" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:53:3-54:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out >= 273.15 and combustion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out <= 373.15, has value: 2200" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.outlet.state.T >= 273.15 and compression.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.outlet.state.T <= 373.15, has value: 753.033" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.adiabaticModel.state_out.T >= 273.15 and compression.adiabaticModel.state_out.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.adiabaticModel.state_out.T <= 373.15, has value: 753.033" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:51:3-52:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 753.033" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.outlet.state.T >= 273.15 and expansion.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.outlet.state.T <= 373.15, has value: 876.455" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.state_in.T >= 273.15 and expansion.adiabaticModel.state_in.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.state_in.T <= 373.15, has value: 2200" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:25:3-26:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.T_in >= 273.15 and expansion.adiabaticModel.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.T_in <= 373.15, has value: 2200" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27:3-27:62:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.T_out_is >= 273.15 and expansion.adiabaticModel.T_out_is <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.T_out_is <= 373.15, has value: 876.455" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.state_out.T >= 273.15 and expansion.adiabaticModel.state_out.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.state_out.T <= 373.15, has value: 876.455" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20:3-20:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.T_out >= 273.15 and expansion.adiabaticModel.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.T_out <= 373.15, has value: 876.455" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:51:3-52:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((gasExchange.T_in >= 273.15 and gasExchange.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= gasExchange.T_in <= 373.15, has value: 876.455" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20:3-20:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.adiabaticModel.T_out >= 273.15 and compression.adiabaticModel.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.adiabaticModel.T_out <= 373.15, has value: 753.033" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27:3-27:62:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.adiabaticModel.T_out_is >= 273.15 and compression.adiabaticModel.T_out_is <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.adiabaticModel.T_out_is <= 373.15, has value: 753.033" info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.010000 info: Result file: ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.AdiabaticPerfectGas_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.combustion.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.compression.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.compression.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.efficiency.description will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.expansion.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.expansion.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.gasExchange.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.loopBreaker.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.maximumPressure.description will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_AdiabaticPerfectGas.netWork.description will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 101 NumRhsEvals = 102 NumLinSolvSetups = 6 NumNonlinSolvIters = 101 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors