/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.AirCycle.Step7BootStrapCycle_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.AirCycle.Step7BootStrapCycle" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.AirCycle.Step7BootStrapCycle" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.AirCycle.Step7BootStrapCycle/model-3a6cb3m4" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.AirCycle.Step7BootStrapCycle" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.010000 warning: [fmi2Warning] ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle/logStatusWarning: The following assertion has been violated during initialization at time 0.000000 LOG_ASSERT | debug | Model error: Argument of log(9.869232667160129e-6 * compressor1.p_out) was -3.81408 should be > 0 error: [fmi2logger] [fmi2Error] ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Utilities/Streams.mo:113: The arguments u_min and u_max provided in the function call solveOneNonlinearEquation(f,u_min,u_max) do not bracket the root of the single non-linear equation 0=f(u): u_min = 200 u_max = 6000 fa = f(u_min) = 10037.5 fb = f(u_max) = 7.32799e+06 fa and fb must have opposite sign which is not the case error: [fmi2logger] [fmi2Error] ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_AirCycle_Step7BootStrapCycle" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 3 warnings info: 5 errors