/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine_fmu --startTime=0 --stopTime=25 --stepSize=0.025 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine/model-l0fjkvi2" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine.fmu - startTime: 0.000000 - stopTime: 25.000000 - tolerance: 0.000001 - stepSize: 0.025000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tanValve1.p_min >= 611.657 and tanValve1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= tanValve1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tanValve.p_min >= 611.657 and tanValve.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= tanValve.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance6.p_min >= 611.657 and flowResistance6.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance6.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance5.p_min >= 611.657 and flowResistance5.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance5.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance4.p_min >= 611.657 and flowResistance4.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance4.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance3.p_min >= 611.657 and flowResistance3.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance3.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((switch.tanValve1.p_min >= 611.657 and switch.tanValve1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= switch.tanValve1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((switch.tanValve.p_min >= 611.657 and switch.tanValve.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= switch.tanValve.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((switchConnector1.checkValve1.p_min >= 611.657 and switchConnector1.checkValve1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= switchConnector1.checkValve1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((switchConnector1.checkValve.p_min >= 611.657 and switchConnector1.checkValve.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= switchConnector1.checkValve.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((switchConnector.checkValve1.p_min >= 611.657 and switchConnector.checkValve1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= switchConnector.checkValve1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((switchConnector.checkValve.p_min >= 611.657 and switchConnector.checkValve.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= switchConnector.checkValve.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((conductionElement.p_min >= 611.657 and conductionElement.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= conductionElement.p_min <= 1e8, has value: 100" error: [fmi2logger] [fmi2Error] ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Water/IF97_Utilities.mo:6796: Error in region computation of IF97 steam tables(p = 100000, h = 1.71165e+07) error: [fmi2logger] [fmi2Error] ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors