(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank_res.mat --stripRoot --tempDir=temp_ThermofluidStream_ThermofluidStream_Boundaries_Tests_TankFillingClosedTank_fmu --startTime=0 --stopTime=20 --stepSize=0.008 --timeout=50 --tolerance=1e-06 ../ThermofluidStream_ThermofluidStream_Boundaries_Tests_TankFillingClosedTank.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : ThermofluidStream.Boundaries.Tests.TankFillingClosedTank (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 20.000000 - tolerance : 1e-06 - stepSize : 0.008 info: maximum step size for 'TankFillingClosedTank.root': 0.008000 info: Result file: ../ThermofluidStream_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank_res.mat (bufferSize=10) info: Variable TankFillingClosedTank.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.flowResistance1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.flowResistance2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.staticHead.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.staticHead1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.tank.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankFillingClosedTank.tank1.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((flowResistance.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Negative massflow at tank inlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((staticHead1.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Negative massflow at tank inlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Boundaries/Internal/PartialTank.mo:154:5-154:138:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((staticHead1.inlet.m_flow > tank1.m_flow_assert)) --> "In "TankFillingClosedTank.tank1": Positive massflow at tank outlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Boundaries/Internal/PartialTank.mo:154:5-154:138:writable] | | | | The following assertion has been violated at time 2.400000 | | | | ((staticHead.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Positive massflow at tank outlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 2.400000 | | | | ((staticHead.inlet.m_flow > tank1.m_flow_assert)) --> "In "TankFillingClosedTank.tank1": Negative massflow at tank inlet" info: Final Statistics for 'TankFillingClosedTank.root': NumSteps = 2584 NumRhsEvals = 2631 NumLinSolvSetups = 144 NumNonlinSolvIters = 2630 NumNonlinSolvConvFails = 0 NumErrTestFails = 6 info: 2 warnings info: 0 errors