/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoPower_ThermoPower_Test_WaterComponents_WaterPumpMech_fmu --startTime=0 --stopTime=25 --stepSize=0.01 --timeout=50 --tolerance=1e-06 ThermoPower_ThermoPower_Test_WaterComponents_WaterPumpMech.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.WaterPumpMech" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.WaterPumpMech" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.WaterPumpMech/model-69a1pibe" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.WaterPumpMech" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermoPower_ThermoPower_Test_WaterComponents_WaterPumpMech.fmu - startTime: 0.000000 - stopTime: 25.000000 - tolerance: 0.000001 - stepSize: 0.010000 error: [fmi2logger] [fmi2Error] ThermoPower_ThermoPower_Test_WaterComponents_WaterPumpMech/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:6433: Error in region computation of IF97 steam tables(p = 101325, h = 0) error: [fmi2logger] [fmi2Error] ThermoPower_ThermoPower_Test_WaterComponents_WaterPumpMech/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.ThermoPower_ThermoPower_Test_WaterComponents_WaterPumpMech" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors