Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.RecompressionCycle.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0008622/0.0008622, allocations: 80.44 kB / 19.17 MB, free: 0.7461 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0009109/0.0009109, allocations: 165.9 kB / 22.45 MB, free: 2.109 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 0.8712/0.8712, allocations: 158.6 MB / 184.2 MB, free: 3.039 MB / 170.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo): time 0.06722/0.06722, allocations: 19.08 MB / 255.6 MB, free: 12.25 MB / 250.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/Utilities/LinProgFunc.mo:6:1-33:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package SolarTherm with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.RecompressionCycle,fileNamePrefix="SolarTherm_SolarTherm_Models_PowerBlocks_sCO2Cycle_DirectDesign_RecompressionCycle",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.RecompressionCycle,fileNamePrefix="SolarTherm_SolarTherm_Models_PowerBlocks_sCO2Cycle_DirectDesign_RecompressionCycle",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.463e-06/1.463e-06, allocations: 0 / 384.9 MB, free: 5.105 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.525e-05/2.671e-05, allocations: 2.281 kB / 384.9 MB, free: 5.102 MB / 314.7 MB Notification: Performance of NFInst.instantiate(SolarTherm.Models.PowerBlocks.sCO2Cycle.DirectDesign.RecompressionCycle): time 0.03002/0.03005, allocations: 47.03 MB / 432 MB, free: 5.906 MB / 362.7 MB Notification: Performance of NFInst.instExpressions: time 0.0054/0.03545, allocations: 4.537 MB / 436.5 MB, free: 1.352 MB / 362.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0006331/0.03608, allocations: 19.88 kB / 436.5 MB, free: 1.332 MB / 362.7 MB Notification: Performance of NFTyping.typeComponents: time 0.001207/0.03729, allocations: 0.6286 MB / 437.1 MB, free: 0.6992 MB / 362.7 MB Notification: Performance of NFTyping.typeBindings: time 0.1846/0.2219, allocations: 1.343 MB / 438.5 MB, free: 17.9 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm master/Models/PowerBlocks/sCO2Cycle/DirectDesign/RecompressionCycle.mo:182:2-182:32:writable] Error: cooler.T_amb is not a valid connector. Notification: Performance of FrontEnd: time 9.195e-05/0.222, allocations: 13.78 kB / 438.5 MB, free: 17.9 MB / 362.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 1.8804101180285215] Failed to read output from testmodel.py, exit status != 0: 0.22697118110954762 0.237372734 -1.0 Calling exit ...