/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat --tempDir=temp_Dynawo_dev_Dynawo_Examples_GridForming_GridForming_fmu --startTime=0 --stopTime=3 --stepSize=0.006 --timeout=50 --tolerance=1e-06 Dynawo_dev_Dynawo_Examples_GridForming_GridForming.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.GridForming.GridForming" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.GridForming.GridForming" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.GridForming.GridForming/model-60zez609" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.GridForming.GridForming" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Dynawo_dev_Dynawo_Examples_GridForming_GridForming.fmu - startTime: 0.000000 - stopTime: 3.000000 - tolerance: 0.000001 - stepSize: 0.006000 LOG_NLS | error | residualFunc1214: Iteration variable `1ÀHƒÄ[A\A]A^A_]Ãfffff.„` is inf or nan. LOG_ASSERT | debug | residualFunc1214 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 0. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V info: maximum step size for 'model.root': 0.006000 info: Result file: Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 311 NumRhsEvals = 325 NumLinSolvSetups = 23 NumNonlinSolvIters = 324 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors