Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.GridForming.GridForming.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.000833/0.000833, allocations: 76.52 kB / 19.95 MB, free: 4.613 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0008892/0.0008892, allocations: 169.2 kB / 23.23 MB, free: 1.332 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 0.8562/0.8562, allocations: 158.6 MB / 185 MB, free: 3.043 MB / 170.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo): time 0.4173/0.4173, allocations: 90.27 MB / 327.5 MB, free: 15.01 MB / 314.7 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.GridForming.GridForming,fileNamePrefix="Dynawo_dev_Dynawo_Examples_GridForming_GridForming",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.GridForming.GridForming,fileNamePrefix="Dynawo_dev_Dynawo_Examples_GridForming_GridForming",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.683e-06/1.683e-06, allocations: 0 / 0.4977 GB, free: 18.35 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.392e-05/2.56e-05, allocations: 9.734 kB / 0.4977 GB, free: 18.34 MB / 442.7 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.GridForming.GridForming): time 0.01176/0.01179, allocations: 14.24 MB / 0.5116 GB, free: 8.711 MB / 442.7 MB Notification: Performance of NFInst.instExpressions: time 0.009839/0.02163, allocations: 5.985 MB / 0.5175 GB, free: 4.367 MB / 442.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.002208/0.02383, allocations: 62.62 kB / 0.5175 GB, free: 4.344 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:23:3-23:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:24:3-24:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:26:3-26:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:27:3-27:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:28:3-28:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:29:3-29:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:32:3-32:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:33:3-33:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:34:3-34:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:35:3-35:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:36:3-36:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:37:3-37:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Converters/GridFormingControl_INIT.mo:38:3-38:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:34:3-34:104:writable] Warning: Connector IdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:35:3-35:98:writable] Warning: Connector UdcSource0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:36:3-36:108:writable] Warning: Connector UdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:37:3-37:108:writable] Warning: Connector UqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:38:3-38:143:writable] Warning: Connector IdConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:39:3-39:143:writable] Warning: Connector IqConv0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:40:3-40:137:writable] Warning: Connector IdPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:41:3-41:137:writable] Warning: Connector IqPcc0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:42:3-42:128:writable] Warning: Connector UdFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:43:3-43:128:writable] Warning: Connector UqFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:44:3-44:145:writable] Warning: Connector Theta0 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:45:3-45:164:writable] Warning: Connector PFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter_INIT.mo:46:3-46:168:writable] Warning: Connector QFilter0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001452/0.02529, allocations: 0.7045 MB / 0.5182 GB, free: 3.887 MB / 442.7 MB Notification: Performance of NFTyping.typeBindings: time 0.002329/0.02762, allocations: 1.091 MB / 0.5193 GB, free: 3.051 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv250.terminal.V.re == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv250.terminal.V.im == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv500.terminal.V.re == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv500.terminal.V.im == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv1000.terminal.V.re == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Sources/Converter.mo:143:5-147:11:writable] Warning: In relation Conv1000.terminal.V.im == 0.0, == on Real operands is deprecated in non-function contexts. Notification: Performance of NFTyping.typeClassSections: time 0.003692/0.03131, allocations: 2.465 MB / 0.5217 GB, free: 1.293 MB / 442.7 MB Notification: Performance of NFFlatten.flatten: time 0.004909/0.03622, allocations: 5.948 MB / 0.5275 GB, free: 13.52 MB / 458.7 MB Notification: Performance of NFFlatten.resolveConnections: time 0.001812/0.03803, allocations: 1.377 MB / 0.5288 GB, free: 12.5 MB / 458.7 MB Notification: Performance of NFEvalConstants.evaluate: time 0.00241/0.04044, allocations: 2.11 MB / 0.5309 GB, free: 11.16 MB / 458.7 MB Notification: Performance of NFSimplifyModel.simplify: time 0.002006/0.04244, allocations: 2.057 MB / 0.5329 GB, free: 9.734 MB / 458.7 MB Notification: Performance of NFPackage.collectConstants: time 0.0007507/0.0432, allocations: 0.573 MB / 0.5335 GB, free: 9.734 MB / 458.7 MB Notification: Performance of NFFlatten.collectFunctions: time 0.0009448/0.04414, allocations: 0.7451 MB / 0.5342 GB, free: 9.684 MB / 458.7 MB Notification: Performance of NFScalarize.scalarize: time 0.0007396/0.04488, allocations: 1.224 MB / 0.5354 GB, free: 8.609 MB / 458.7 MB Notification: Performance of NFVerifyModel.verify: time 0.001128/0.04601, allocations: 1.703 MB / 0.537 GB, free: 6.91 MB / 458.7 MB Notification: Performance of NFConvertDAE.convert: time 0.004307/0.05031, allocations: 6.9 MB / 0.5438 GB, free: 15.98 MB / 474.7 MB Notification: Performance of FrontEnd - DAE generated: time 3.156e-06/0.05032, allocations: 0 / 0.5438 GB, free: 15.98 MB / 474.7 MB Notification: Performance of FrontEnd: time 1.673e-06/0.05032, allocations: 0 / 0.5438 GB, free: 15.98 MB / 474.7 MB Notification: Performance of Transformations before backend: time 5.466e-05/0.05037, allocations: 0 / 0.5438 GB, free: 15.98 MB / 474.7 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 932 * Number of variables: 932 Notification: Performance of Generate backend data structure: time 0.008214/0.05859, allocations: 6.348 MB / 0.55 GB, free: 9.512 MB / 474.7 MB Notification: Performance of prepare preOptimizeDAE: time 4.665e-05/0.05863, allocations: 8.031 kB / 0.55 GB, free: 9.504 MB / 474.7 MB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0004368/0.05907, allocations: 0.4981 MB / 0.5505 GB, free: 8.996 MB / 474.7 MB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.002572/0.06164, allocations: 1.161 MB / 0.5516 GB, free: 7.832 MB / 474.7 MB Notification: Performance of preOpt evaluateParameters (simulation): time 0.002504/0.06415, allocations: 2.208 MB / 0.5538 GB, free: 5.578 MB / 474.7 MB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0004701/0.06462, allocations: 1.099 MB / 0.5548 GB, free: 4.309 MB / 474.7 MB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0003842/0.065, allocations: 412.3 kB / 0.5552 GB, free: 3.906 MB / 474.7 MB Notification: Performance of preOpt clockPartitioning (simulation): time 0.004843/0.06984, allocations: 4.52 MB / 0.5596 GB, free: 15.14 MB / 490.7 MB Notification: Performance of preOpt findStateOrder (simulation): time 4.611e-05/0.06989, allocations: 7.938 kB / 0.5597 GB, free: 15.13 MB / 490.7 MB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0002621/0.07015, allocations: 160 kB / 0.5598 GB, free: 14.98 MB / 490.7 MB Notification: Performance of preOpt inlineArrayEqn (simulation): time 4.553e-05/0.0702, allocations: 95.94 kB / 0.5599 GB, free: 14.88 MB / 490.7 MB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.004045/0.07424, allocations: 3.363 MB / 0.5632 GB, free: 11.51 MB / 490.7 MB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.0161/0.09034, allocations: 17.65 MB / 0.5804 GB, free: 9.48 MB / 0.4948 GB Notification: Performance of preOpt comSubExp (simulation): time 0.00453/0.09487, allocations: 3.643 MB / 0.584 GB, free: 5.766 MB / 0.4948 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.002265/0.09714, allocations: 1.985 MB / 0.5859 GB, free: 3.754 MB / 0.4948 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0001898/0.09733, allocations: 50.39 kB / 0.586 GB, free: 3.703 MB / 0.4948 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.002945/0.1003, allocations: 2.576 MB / 0.5885 GB, free: 1.066 MB / 0.4948 GB Notification: Performance of pre-optimization done (n=411): time 6.072e-06/0.1003, allocations: 0 / 0.5885 GB, free: 1.066 MB / 0.4948 GB Notification: Performance of matching and sorting (n=411): time 0.01577/0.116, allocations: 8.115 MB / 0.5964 GB, free: 8.887 MB / 0.5105 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.000121/0.1162, allocations: 289.9 kB / 0.5967 GB, free: 8.547 MB / 0.5105 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00276/0.1189, allocations: 2.826 MB / 0.5994 GB, free: 5.719 MB / 0.5105 GB Notification: Performance of collectPreVariables (initialization): time 0.0002272/0.1192, allocations: 121.7 kB / 0.5996 GB, free: 5.594 MB / 0.5105 GB Notification: Performance of collectInitialEqns (initialization): time 0.0009237/0.1201, allocations: 1.562 MB / 0.6011 GB, free: 4.016 MB / 0.5105 GB Notification: Performance of collectInitialBindings (initialization): time 0.001179/0.1213, allocations: 1.472 MB / 0.6025 GB, free: 2.531 MB / 0.5105 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.001185/0.1224, allocations: 1.156 MB / 0.6036 GB, free: 1.367 MB / 0.5105 GB Notification: Performance of setup shared object (initialization): time 6.758e-05/0.1225, allocations: 301.1 kB / 0.6039 GB, free: 1.07 MB / 0.5105 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.002821/0.1253, allocations: 2.501 MB / 0.6064 GB, free: 14.55 MB / 0.5261 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.003306/0.1286, allocations: 3.326 MB / 0.6096 GB, free: 11 MB / 0.5261 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.01955/0.1482, allocations: 14.05 MB / 0.6233 GB, free: 12.39 MB / 0.5417 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.532e-05/0.1482, allocations: 7.938 kB / 0.6234 GB, free: 12.39 MB / 0.5417 GB Notification: Performance of matching and sorting (n=892) (initialization): time 0.01267/0.1609, allocations: 8.8 MB / 0.6319 GB, free: 3.488 MB / 0.5417 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001355/0.161, allocations: 173.5 kB / 0.6321 GB, free: 3.312 MB / 0.5417 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 2.471e-05/0.161, allocations: 16 kB / 0.6321 GB, free: 3.297 MB / 0.5417 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.2627/0.4237, allocations: 57.09 MB / 0.6879 GB, free: 162.1 MB / 0.5886 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.007696/0.4314, allocations: 1.702 MB / 0.6895 GB, free: 162.1 MB / 0.5886 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01457/0.446, allocations: 16.67 MB / 0.7058 GB, free: 150.7 MB / 0.5886 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.002707/0.4487, allocations: 0.5522 MB / 0.7064 GB, free: 150.6 MB / 0.5886 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.000296/0.449, allocations: 237.1 kB / 0.7066 GB, free: 150.5 MB / 0.5886 GB Warning: Assuming fixed start value for the following 48 variables: Line12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line12.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line23.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line23Bis1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23Bis1.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Line23Bis2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Line23Bis2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Conv1000.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv1000.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Conv500.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv500.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Conv250.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Conv250.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Droop.droopControl.firstOrder.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder.y_start fixed = true ) \"Connector of Real output signal\" type: Real Droop.droopControl.firstOrder1.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder1.y_start fixed = true ) \"Connector of Real output signal\" type: Real Droop.droopControl.firstOrder2.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder2.y_start fixed = true ) \"Connector of Real output signal\" type: Real Droop.droopControl.firstOrder3.y:VARIABLE(flow=false start = Droop.droopControl.firstOrder3.y_start fixed = true ) \"Connector of Real output signal\" type: Real Conv250.running:DISCRETE(flow=false start = Conv250.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Conv250.udFilterPu:VARIABLE(flow=false start = Conv250.UdFilter0Pu fixed = true ) \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv250.uqFilterPu:VARIABLE(flow=false start = Conv250.UqFilter0Pu fixed = true ) \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv250.idConvPu:VARIABLE(flow=false start = Conv250.IdConv0Pu fixed = true ) \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.iqConvPu:VARIABLE(flow=false start = Conv250.IqConv0Pu fixed = true ) \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.idPccPu:VARIABLE(flow=false start = Conv250.IdPcc0Pu fixed = true ) \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.iqPccPu:VARIABLE(flow=false start = Conv250.IqPcc0Pu fixed = true ) \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv250.UdcSourcePu:VARIABLE(flow=false start = Droop.dCVoltageControl.UdcSource0Pu fixed = true ) \"DC voltage in pu (base UdcNom)\" type: Real dVOC.dispatchableVirtualOscillatorControl.UFilterRefRawPu:VARIABLE(start = dVOC.dispatchableVirtualOscillatorControl.UFilterRef0Pu unit = \"1\" fixed = true ) type: Real Conv500.running:DISCRETE(flow=false start = Conv500.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Conv500.udFilterPu:VARIABLE(flow=false start = Conv500.UdFilter0Pu fixed = true ) \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv500.uqFilterPu:VARIABLE(flow=false start = Conv500.UqFilter0Pu fixed = true ) \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv500.idConvPu:VARIABLE(flow=false start = Conv500.IdConv0Pu fixed = true ) \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.iqConvPu:VARIABLE(flow=false start = Conv500.IqConv0Pu fixed = true ) \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.idPccPu:VARIABLE(flow=false start = Conv500.IdPcc0Pu fixed = true ) \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.iqPccPu:VARIABLE(flow=false start = Conv500.IqPcc0Pu fixed = true ) \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv500.UdcSourcePu:VARIABLE(flow=false start = dVOC.dCVoltageControl.UdcSource0Pu fixed = true ) \"DC voltage in pu (base UdcNom)\" type: Real Conv1000.running:DISCRETE(flow=false start = Conv1000.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Conv1000.udFilterPu:VARIABLE(flow=false start = Conv1000.UdFilter0Pu fixed = true ) \"d-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv1000.uqFilterPu:VARIABLE(flow=false start = Conv1000.UqFilter0Pu fixed = true ) \"q-axis voltage at the converter's capacitor in pu (base UNom)\" type: Real Conv1000.idConvPu:VARIABLE(flow=false start = Conv1000.IdConv0Pu fixed = true ) \"d-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.iqConvPu:VARIABLE(flow=false start = Conv1000.IqConv0Pu fixed = true ) \"q-axis current in the converter in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.idPccPu:VARIABLE(flow=false start = Conv1000.IdPcc0Pu fixed = true ) \"d-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.iqPccPu:VARIABLE(flow=false start = Conv1000.IqPcc0Pu fixed = true ) \"q-axis current in the grid in pu (base UNom, SNom) (generator convention)\" type: Real Conv1000.UdcSourcePu:VARIABLE(flow=false start = Matching.matchingControl.UdcSource0Pu fixed = true ) \"DC voltage in pu (base UdcNom)\" type: Real Line12.running:DISCRETE(flow=false start = Line12.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Line13.running:DISCRETE(flow=false start = Line13.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Line23.running:DISCRETE(flow=false start = Line23.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Line23Bis1.running:DISCRETE(flow=false start = Line23Bis1.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Line23Bis2.running:DISCRETE(flow=false start = Line23Bis2.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Load.running:DISCRETE(flow=false start = Load.Running0 fixed = true ) \"Indicates if the component is running or not\" type: Boolean Fault.nodeFault:DISCRETE(flow=false start = false fixed = true ) \"True when the fault is ongoing, false otherwise\" type: Boolean Conv1000.IConv0Pu:VARIABLE(unit = \"1\" fixed = true ) \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real Conv500.IConv0Pu:VARIABLE(unit = \"1\" fixed = true ) \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real Conv250.IConv0Pu:VARIABLE(unit = \"1\" fixed = true ) \"Start value of module of the current injected by the converter in pu (base UNom, SNom)\" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 72 * Number of states: 0 () * Number of discrete variables: 107 ($PRE.Line12.state,Line12.state,$PRE.Line13.state,Line13.state,$PRE.Line23.state,Line23.state,$PRE.Line23Bis1.state,Line23Bis1.state,$PRE.Line23Bis2.state,Line23Bis2.state,$PRE.Load.state,Load.state,$whenCondition1,$whenCondition2,$PRE.Conv1000.state,Conv1000.converter.u,Conv1000.state,$PRE.Conv500.state,Conv500.converter.u,Conv500.state,$PRE.Conv250.state,Conv250.converter.u,Conv250.state,Conv1000.switchOffSignal3,Conv1000.switchOffSignal2,Conv1000.switchOffSignal1,Conv500.switchOffSignal3,Conv500.switchOffSignal2,Conv500.switchOffSignal1,Conv250.switchOffSignal3,Conv250.switchOffSignal2,Conv250.switchOffSignal1,Load.switchOffSignal2,Load.switchOffSignal1,Line23Bis2.switchOffSignal2,Line23Bis2.switchOffSignal1,Line23Bis1.switchOffSignal2,Line23Bis1.switchOffSignal1,Line23.switchOffSignal2,Line23.switchOffSignal1,Line13.switchOffSignal2,Line13.switchOffSignal1,Line12.switchOffSignal1,$PRE.Conv250.running,$PRE.Conv500.running,$PRE.Conv1000.running,$PRE.Line12.running,$PRE.Line13.running,$PRE.Line23.running,$PRE.Line23Bis1.running,$PRE.Line23Bis2.running,$PRE.Load.running,$PRE.Fault.nodeFault,Fault.nodeFault,Load.running,Line23Bis2.running,Line23Bis1.running,Line23.running,Line13.running,Line12.running,Line12.switchOffSignal2,Conv1000.running,Conv500.running,Conv250.running,$whenCondition3,$whenCondition5,$whenCondition4,$whenCondition6,$whenCondition8,$whenCondition7,$whenCondition9,$whenCondition11,$whenCondition10,$whenCondition12,$whenCondition14,$whenCondition13,$whenCondition15,$whenCondition17,$whenCondition16,$whenCondition19,$whenCondition18,$whenCondition21,$whenCondition20,$whenCondition22,$whenCondition24,$whenCondition23,$whenCondition25,$whenCondition27,$whenCondition26,$whenCondition28,$whenCondition30,$whenCondition29,Matching.matchingControl.integrator.local_reset,Matching.voltageLoop.integratorq.local_reset,Matching.voltageLoop.integratord.local_reset,Matching.currentLoop.integratorq.local_reset,Matching.currentLoop.integratord.local_reset,dVOC.dispatchableVirtualOscillatorControl.integrator.local_reset,dVOC.voltageLoop.integratorq.local_reset,dVOC.voltageLoop.integratord.local_reset,dVOC.currentLoop.integratorq.local_reset,dVOC.currentLoop.integratord.local_reset,Droop.droopControl.integrator.local_reset,Droop.voltageLoop.integratorq.local_reset,Droop.voltageLoop.integratord.local_reset,Droop.currentLoop.integratorq.local_reset,Droop.currentLoop.integratord.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (726): * Single equations (assignments): 716 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 3 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 3 systems {(2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 4 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 3 systems {(24,10), (1,1), (12,7)} Notification: Performance of prepare postOptimizeDAE: time 0.001647/0.4507, allocations: 1.009 MB / 0.7076 GB, free: 149.9 MB / 0.5886 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.0004203/0.4511, allocations: 420.6 kB / 0.708 GB, free: 149.9 MB / 0.5886 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.00894/0.46, allocations: 5.675 MB / 0.7135 GB, free: 147.6 MB / 0.5886 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 3.178e-05/0.4601, allocations: 40.53 kB / 0.7136 GB, free: 147.6 MB / 0.5886 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.945e-05/0.4601, allocations: 8.516 kB / 0.7136 GB, free: 147.5 MB / 0.5886 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 3.167e-05/0.4601, allocations: 22.67 kB / 0.7136 GB, free: 147.5 MB / 0.5886 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.01327/0.4734, allocations: 9.617 MB / 0.723 GB, free: 143.3 MB / 0.5886 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.01e-05/0.4734, allocations: 3.703 kB / 0.723 GB, free: 143.3 MB / 0.5886 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.005092/0.4785, allocations: 1.195 MB / 0.7241 GB, free: 143.2 MB / 0.5886 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.001717/0.4802, allocations: 1.278 MB / 0.7254 GB, free: 142.8 MB / 0.5886 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.000226/0.4804, allocations: 100.4 kB / 0.7255 GB, free: 142.7 MB / 0.5886 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.01507/0.4955, allocations: 40.4 MB / 0.7649 GB, free: 102.5 MB / 0.5886 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.254e-06/0.4955, allocations: 8.094 kB / 0.765 GB, free: 102.5 MB / 0.5886 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01038/0.5059, allocations: 8.138 MB / 0.7729 GB, free: 95.09 MB / 0.5886 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0006423/0.5065, allocations: 471.3 kB / 0.7734 GB, free: 94.71 MB / 0.5886 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0002947/0.5068, allocations: 91.22 kB / 0.7734 GB, free: 94.62 MB / 0.5886 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.001067/0.5079, allocations: 113.9 kB / 0.7735 GB, free: 94.53 MB / 0.5886 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0006541/0.5085, allocations: 344 kB / 0.7739 GB, free: 94.36 MB / 0.5886 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0001593/0.5087, allocations: 130 kB / 0.774 GB, free: 94.25 MB / 0.5886 GB Notification: Performance of sorting global known variables: time 0.001498/0.5102, allocations: 1.721 MB / 0.7757 GB, free: 92.54 MB / 0.5886 GB Notification: Performance of sort global known variables: time 8e-08/0.5102, allocations: 0 / 0.7757 GB, free: 92.54 MB / 0.5886 GB Notification: Performance of remove unused functions: time 0.002734/0.5129, allocations: 1.393 MB / 0.777 GB, free: 91.16 MB / 0.5886 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 10 * Number of states: 41 (Droop.currentLoop.integratord.y,Droop.currentLoop.integratorq.y,Droop.voltageLoop.integratord.y,Droop.voltageLoop.integratorq.y,Droop.droopControl.firstOrder.y,Droop.droopControl.integrator.y,Droop.droopControl.firstOrder1.y,Droop.droopControl.firstOrder2.y,Droop.droopControl.firstOrder3.y,Conv250.udFilterPu,Conv250.uqFilterPu,Conv250.idConvPu,Conv250.iqConvPu,Conv250.idPccPu,Conv250.iqPccPu,Conv250.UdcSourcePu,dVOC.currentLoop.integratord.y,dVOC.currentLoop.integratorq.y,dVOC.voltageLoop.integratord.y,dVOC.voltageLoop.integratorq.y,dVOC.dispatchableVirtualOscillatorControl.integrator.y,dVOC.dispatchableVirtualOscillatorControl.UFilterRefRawPu,Conv500.udFilterPu,Conv500.uqFilterPu,Conv500.idConvPu,Conv500.iqConvPu,Conv500.idPccPu,Conv500.iqPccPu,Conv500.UdcSourcePu,Matching.currentLoop.integratord.y,Matching.currentLoop.integratorq.y,Matching.voltageLoop.integratord.y,Matching.voltageLoop.integratorq.y,Matching.matchingControl.integrator.y,Conv1000.udFilterPu,Conv1000.uqFilterPu,Conv1000.idConvPu,Conv1000.iqConvPu,Conv1000.idPccPu,Conv1000.iqPccPu,Conv1000.UdcSourcePu) * Number of discrete variables: 53 ($whenCondition29,$whenCondition30,$whenCondition28,$whenCondition26,$whenCondition27,$whenCondition25,$whenCondition23,$whenCondition24,$whenCondition22,$whenCondition20,$whenCondition21,$whenCondition18,$whenCondition19,$whenCondition16,$whenCondition17,$whenCondition15,$whenCondition13,$whenCondition14,$whenCondition12,$whenCondition10,$whenCondition11,$whenCondition9,$whenCondition7,$whenCondition8,$whenCondition6,$whenCondition4,$whenCondition5,$whenCondition3,$whenCondition1,$whenCondition2,Conv250.running,Conv250.state,Conv250.converter.u,Conv500.running,Conv500.state,Conv500.converter.u,Conv1000.running,Conv1000.state,Conv1000.converter.u,Line12.switchOffSignal2,Line12.running,Line12.state,Line13.running,Line13.state,Line23.running,Line23.state,Line23Bis1.running,Line23Bis1.state,Line23Bis2.running,Line23Bis2.state,Load.running,Load.state,Fault.nodeFault) * Number of discrete states: 9 (Conv250.running,Conv500.running,Conv1000.running,Line13.running,Line23.running,Line23Bis1.running,Line23Bis2.running,Load.running,Line12.running) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (371): * Single equations (assignments): 322 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 19 * If-equations: 0 * Equation systems (not torn): 24 * Torn equation systems: 6 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 3 systems {(2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 21 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 4 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 2 systems {(1,1), (24,10)} Notification: Performance of Backend phase and start with SimCode phase: time 0.009897/0.5228, allocations: 8.896 MB / 0.7857 GB, free: 82.17 MB / 0.5886 GB Notification: Performance of simCode: created initialization part: time 0.007287/0.5301, allocations: 6.801 MB / 0.7924 GB, free: 75.25 MB / 0.5886 GB Notification: Performance of simCode: created event and clocks part: time 3.537e-06/0.5301, allocations: 0 / 0.7924 GB, free: 75.25 MB / 0.5886 GB Notification: Performance of simCode: created simulation system equations: time 0.004797/0.5349, allocations: 3.502 MB / 0.7958 GB, free: 71.66 MB / 0.5886 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.001661/0.5366, allocations: 0.5438 MB / 0.7963 GB, free: 71.15 MB / 0.5886 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.05079/0.5874, allocations: 41.55 MB / 0.8369 GB, free: 28.69 MB / 0.5886 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.001081/0.5884, allocations: 1.683 MB / 0.8385 GB, free: 26.97 MB / 0.5886 GB Notification: Performance of simCode: alias equations: time 0.001276/0.5897, allocations: 407.5 kB / 0.8389 GB, free: 26.57 MB / 0.5886 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.001369/0.5911, allocations: 1.789 MB / 0.8407 GB, free: 24.78 MB / 0.5886 GB Notification: Performance of SimCode: time 1.142e-06/0.5911, allocations: 0 / 0.8407 GB, free: 24.78 MB / 0.5886 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.3121/0.9032, allocations: 102.5 MB / 0.9408 GB, free: 212.1 MB / 0.6511 GB Notification: Performance of buildModelFMU: Generate platform static: time 12.79/13.7, allocations: 7.625 kB / 0.9408 GB, free: 212.1 MB / 0.6511 GB " [Timeout remaining time 646] (rm -f Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe ; mkfifo Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe ; head -c 1048576 < Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe >> ../files/Dynawo_dev_Dynawo.Examples.GridForming.GridForming.sim & /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat --tempDir=temp_Dynawo_dev_Dynawo_Examples_GridForming_GridForming_fmu --startTime=0 --stopTime=3 --stepSize=0.006 --timeout=50 --tolerance=1e-06 Dynawo_dev_Dynawo_Examples_GridForming_GridForming.fmu > Dynawo_dev_Dynawo.Examples.GridForming.GridForming.pipe 2>&1) [Timeout 52.5] diffSimulationResults("Dynawo_dev_Dynawo.Examples.GridForming.GridForming_res.mat","/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ReferenceFiles/Dynawo/dynawo/sources/Models/Modelica/Dynawo/Examples/references/Dynawo.Examples.GridForming.GridForming_res.csv","/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/Dynawo_dev_Dynawo.Examples.GridForming.GridForming.diff",relTol=0.003,relTolDiffMinMax=0.003,rangeDelta=0.001) [Timeout 660] "" [Timeout remaining time 660] Reference file matches [Calling sys.exit(0), Time elapsed: 17.246818454936147]