(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_HeatPumps_Calibration_ScrollWaterToWater_fmu --startTime=0 --stopTime=142 --stepSize=0.0568 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_HeatPumps_Calibration_ScrollWaterToWater.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Fluid.HeatPumps.Calibration.ScrollWaterToWater (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 142.000000 - tolerance : 1e-06 - stepSize : 0.0568 LOG_STDOUT | info | ... loading "ManufacturerData" from "/tmp/tmp5x5vq_xu/ScrollWaterToWater-ahip0a7e/temp/0001_ScrollWaterToWater/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/src/fluid/heatpumps/calibration/manufacturerData.txt" info: model doesn't contain any continuous state info: maximum step size for 'ScrollWaterToWater.root': 0.056800 info: Result file: Buildings_13_Buildings_Fluid_HeatPumps_Calibration_ScrollWaterToWater_res.mat (bufferSize=10) info: Parameter ScrollWaterToWater.calDat.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ScrollWaterToWater.calDat.tableName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Refrigerants/R410A/specificVolumeVap_pT.mo:24: Failed to converge in Buildings.Media.Refrigerants.R410A.specificVolumeVap_pT error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [completedIntegratorStep] fmi2_completedIntegratorStep failed for FMU "ScrollWaterToWater.root.ScrollWaterToWater" warning: Bad return code at time 10.053600 error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Refrigerants/R410A/specificVolumeVap_pT.mo:24: Failed to converge in Buildings.Media.Refrigerants.R410A.specificVolumeVap_pT error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sin2.verifyInputs Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 140, in _runFMU fmu.simulate() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 904, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: Final Statistics for 'ScrollWaterToWater.root': NumSteps = 3 NumRhsEvals = 4 NumLinSolvSetups = 3 NumNonlinSolvIters = 3 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 6 errors